Creating a Battery Cell

Create a battery cell in Simcenter Battery Design Studio.

Use the Li-Ion stack cell that is available in Simcenter Battery Design Studio as a starting point.

To create a battery cell in Simcenter Battery Design Studio:

  1. Launch Simcenter Battery Design Studio.
  2. Create a workspace by selecting File > New Workspace.


    The New Workspace dialog appears.
  3. Enter BasicCell as the Name in the textbox, and select an appropriate location.


  4. Click OK.
  5. If the location does not exist, confirm the directory creation.

Components of the battery are created using the tree on the left of the Simcenter Battery Design Studio interface. Create a battery cell.

  1. Right-click the Batteries folder and select Add New Battery > LiIon Stack > LiIonStack.


    A new node, LiIonStack, is added below the Batteries node folder, and a corresponding .tbm file is created in the workspace directory.

The cell can be renamed immediately after it is created.

  1. Rename the battery cell TutorialCell.


  2. To see a diagram of the battery cell, select Main in the TutorialCell.tbm feature tree.


The position of the tabs on each electrode is specified using an offset value. To reposition the tabs, change the offset values.
  1. In the TutorialCell.tbm window, select the + Electrode node and set Tab offset (Otab) to 3.500.


  2. Select the + Electrode > Formulation node and set Single Side Coat Thickness to 0.15.


  3. Select the - Electrode node and set Tab offset (Otab) to 50.500.
  4. Select the - Electrode > Formulation node and set Single Side Coat Thickness to 0.145.

Select a battery model. This model defines how the battery behaves in response to different electrical loads. In this tutorial, the NTGPTable 3D model is used.

  1. Scroll down to the Models node in the TutorialCell.tbm window, and select the NTGPTable 3D model from the IET folder.


The addition of a * to the TutorialCell.tbm window title indicates that you have changed the cell definition. Once the asterisk appears, Build the cell. This process rewrites the .tbm file in the workspace directory and prompts Simcenter Battery Design Studio to check the cell definition for any invalid changes.

  1. Right-click the Batteries > TutorialCell node in the Simcenter Battery Design Studio feature tree and select Build.


  2. If prompted to save, accept.
    A message box appears informing you that the build was successful.
  3. Click OK to close the message box.
The cell definition is complete.