Cylindrical Cells: Cell Thermal Analysis
This tutorial demonstrates how to model a battery module in Simcenter STAR-CCM+ using cylindrical cells. It simulates three cylindrical cells in series in a staggered configuration with an external casing.
The tbm file, prg file, a tab connector, and the external casing, are imported into Simcenter STAR-CCM+.
Note |
For battery modeling, Simcenter STAR-CCM+ requires a batterysim license in addition to the other license features. |
The three cylindrical cells are connected in series and are discharged for 200 seconds with a load of 22.11 A. The cells are cooled with a draft of 1 m/s. You model both the heat generation in the battery and the air flow in the external casing.