Create maximum and minimum temperature reports, monitors, and plots to
visualize the temperature rise of the cells.
-
Create the maximum temperature report.
-
Right-click the Reports node and select .
A new report, Maximum 1, is
created.
-
Rename the Maximum 1 node to Maximum
Temperature.
-
Select the node and set the following properties:
Property |
Setting |
Field Function |
Temperature |
Units |
C |
Parts |
Click
(Custom Editor)In the
Maximum Temperature -
Parts dialog, expand the
Regions node and select the
three Jellyroll regions. |
-
Click OK.
-
Create the minimum temperature report.
-
Right-click the Reports node and select .
-
Rename the node to Minimum Temperature.
-
Select the node and set the following properties:
Property |
Setting |
Field Function |
Temperature |
Units |
C |
Parts |
Click (Custom
Editor)In
the Minimum Temperature -
Parts dialog, expand the
Regions node and select the
three Jellyroll regions. |
-
Click OK.
-
Create a monitor and plot with the temperature reports:
-
Multi-select the following nodes then right-click one of the selected
nodes and select Create Monitor and Plot from
Report.
-
In the Create Plot From Reports...
dialog, click Single Plot.
The
Maximum Temperature Monitor,
Minimum Temperature Monitor, and
Reports Plot nodes appear in the
simulation tree.
-
Rename to Temperature Monitor Plot.
-
Select the node and set Title to
Temperature (C).
-
Create a state of charge report, monitor, and plot to visualize the discharging
of the cells.
-
Right-click the Reports node and select .
A new report, Volume Average
1, is created.
-
Rename the Volume Average 1 node to
State of Charge.
-
Select the node and set the following properties:
Property |
Setting |
Field Function |
|
Parts |
Click (Custom
Editor)In the State of Charge - Parts
dialog, expand the Regions
node and select the three Jellyroll
regions. |
-
Click OK.
-
Right-click the node and select Create Monitor and Plot from
Report.
-
Save the simulation.