Visualizing the Results

Visualize the effect of the draft in the external casing.

The scalar scene of temperature appears as follows.



Create a scalar scene to visualize the effect of the draft in the external casing.

To visualize the results:

  1. Right-click the Scenes > Temperature Scene node and click Copy.
  2. Right-click the Scenes node and click Paste.
    A new scene, Temperature Scene copy, appears in the simulation tree.
  3. Rename Temperature Scene copy to Temperature Plane Section Scene.
  4. Open the Temperature Plane Section Scene.
  5. Right-click the Derived Parts node and select New > Section > Plane Section.
    The Create Plane Section panel appears.
  6. Set normal to [0 m, 1 m, 0 m] as shown below.


  7. Set Display to No Displayer.
  8. Click Create, and then Close.
  9. Select Scenes > Temperature Plane Section Scene > Scalar 1 > Parts and click (Custom Editor) for the Parts property.
    The Parts dialog appears.
  10. Click the Column selection button twice to deselect all parts.
  11. Expand the Derived Parts node and select Plane Section.


  12. Click OK.

As expected, the temperature is lower near the inlet.



The battery state of charge has dropped to 80% as expected.



The temperature of the cells has risen by 14 C during the discharging process.