Setting Up a Voltage Monitor
Define a voltage monitor to show the voltage of the battery over the course of the simulation.
To set up a voltage monitor:
- Right-click Reports.
-
Select
.
A new Volume Average 1 node appears under the Reports node.
- Rename the Voltage. node to
- Select the node.
- In the Voltage Properties window, set Field Function to .
-
Click
(Custom Editor) to the right of the Parts property.
The Voltage - Parts dialog appears. - Expand the Regions node.
- Select Battery Module: Battery Module Cell 0,0. Battery Module: Battery Module Cell 0,0: Stack and then click OK to close the dialog.
-
Right-click the
Create Monitor and Plot from Report.
node and select
A new Voltage Monitor node appears under the Monitors node and a new Voltage Monitor Plot node appears under the Plots node.
The
node lets you monitor the voltage of the battery with time.- Select the node.
- In the Voltage Monitor - Properties window, make sure that Trigger is set to Time Step.
- To open the Voltage Monitor Plot, double-click the node.