Field Function Monitor Reference

Field Function Monitor Properties

Publish Mean

For the Field Variance and Field Co-Variance monitors, determines whether Simcenter STAR-CCM+ will generate a separate field function of the mean of the function being sampled. Two separate properties exist for the Field Co-Variance monitor’s field function selections: Publish Mean 1 and Publish Mean 2.

Activated

Enables this feature.

Deactivated

Leaves this feature disabled.

Field Function

One or more field functions which the monitor is to sample in order to perform its calculations. Two separate properties exist for the Field Co-Variance monitor’s field function selections: FieldFunction 1 and FieldFunction 2.

Trigger

Provides choices for triggering the action:

Iteration

Calculates based on the specified number of iterations in the Frequency property.

If you wish to average results per iteration, it is recommended that you first read the section on choosing between steady and unsteady models.

Time-Step

Calculates based on the specified number of time-steps in the Frequency property (default).

Inactive

No sample is taken.

Parts

The model parts over which the field function monitor collects samples. Opens the in-place part selector for editing.

Sample Count

The number of data samples collected for each cell within the monitor (read-only).

Enable sliding sample window

Calculates a set of the most recent samples, with the number of samples in that set specified by the user. Activates the Sliding Sample Window Size node.

Activated

Enables this feature.

Deactivated

Leaves this feature disabled.

Title

The name of the field function which contains the values computed by the field function monitor (read-only).

Collection Start

The solution step at which to begin collecting data. Samples will be collected at time-steps or iterations after this start time, based on the Frequency property.

Enable collection stop

Specifies the final sample time or iteration after which to stop collecting data. Activates the Stop Specification node.

Activated

Enables this feature.

Deactivated

Leaves this feature disabled.

Frequency

Determines how often the sample will be taken, based on the setting in Trigger. Samples are taken when the number of samples is evenly divisible by the frequency.

Field Function Monitor Pop-Up Menu

Reset Monitor Data

Clears all samples and accumulated data from the field function monitor.