Setting Up a Monitor

By default Simcenter STAR-CCM+ produces a residuals plot which can be used to monitor the convergence of the solution. It is useful to create other monitors to help in assessing convergence of the solution. Monitor the temperature at a point inside the fluid domain, close to the solid-fluid interface.

  1. Click the Mesh Scene 1 tab in the Graphics window.
  2. Right-click the Derived Parts node and create a new point probe with the following settings:
    Property Setting
    Input Parts [Fluid, Surface Extruder] (default)
    Point [0.251, 0.107, -0.0405] m
    Display No Displayer
  3. Click Create then Close.

Use this point to monitor the temperature in the fluid. Before you can create the monitor, first create a report. In this case use a Maximum report:

  1. Right-click the Reports node and select New > User > Maximum.
  2. Rename the Reports > Maximum 1 node to Temperature Point.

Reports can be created for all derived parts and boundaries. In this case, select the point:

  1. Edit the Reports > Temperature Point node and set the following properties:
    Property Setting
    Field Function Temperature
    Parts Derived Parts > Point
    Smooth Values Activated
    The report settings are now complete and you can proceed by creating a monitor and plot from the report.
  2. Right-click the Temperature Point node and select Create Monitor and Plot from Report.
    The monitor and plot are named Temperature Point Monitor and Temperature Point Monitor Plot, respectively.