Creating a Plot of Sound Pressure Level

The spectral analysis plot takes its data from the fast Fourier transform created previously.

To create a plot of sound pressure level:
  1. Right-click the Plots node and select New Plot > Monitor Plot.
  2. Rename the Monitor Plot 1 node to FFT.
  3. Right-click the FFT > Data Series node and select Add Data.
    The Add Data Providers to Plot dialog opens.
  4. In this dialog, select and expand Derived Data, then select the following items:
    • OTF_FWH_Minus90deg100r
    • OTF_FWH_Plus90deg100r
    • Post_FWH_Minus90deg100r
    • Post_FWH_Plus90deg100r
  5. Select the FFT > Axes > Bottom Axis node and set the following properties:
    Property Setting
    Logarithmic Activated
    Minimum 100.0
    Maximum 10000.0
  6. Select the FFT node and set Title to On-The-Fly FW-H and Post FW-H.
The final plot appears similar to the one shown below.

The Post FW-H model allows you to obtain noise prediction at receiver locations not defined in the original unsteady simulation. As the computational cost of running a Post FW-H analysis is much lower than the cost of running an unsteady analysis, you can continue to explore the solution space for little extra effort.