Defining Connection Settings

Define the remaining co-simulation settings, including the details for launching Simcenter Nastran, the concurrency mode, and the coupling time interval at which the simulations exchange data.

Set the remaining options under the co-simulation link:
  1. Expand the External Links > Link 1 > Conditions node and set the following properties:
    Node Property Setting
    Simcenter Nastran Version Version 2306
    Launch Partner Option Option Launch Application

    This setting instructs Simcenter STAR-CCM+ to launch the Simcenter Nastran solver automatically.

    Concurrency Option Option Lag

    When you launch the co-simulation, Simcenter Nastran runs first and Simcenter STAR-CCM+ waits for initial data. This is the only option available for co-simulation with Simcenter Nastran.

    Coupling Negotiation Option Option Time-Step

    With this setting, the time interval at which the simulations exchange data is equal to the Simcenter STAR-CCM+ simulation time-step.

    Mapping Option Option Map Both Directions

    Simcenter STAR-CCM+ is responsible for interpolating both the imported and exported fields to the relevant mesh. This is the only option available for co-simulation with Simcenter Nastran.

To allow Simcenter STAR-CCM+ to launch Simcenter Nastran automatically, specify the location of the Simcenter Nastran input file and executable:
  1. Select the Link 1 > Values node and set the following properties:
    Node Property Setting
    Simcenter Nastran Input File Simcenter Nastran Input File [WORKING_DIRECTORY]\NastranCoSimulation_Tutorial\Nastran\disc_fem1_sim1-solution_1.dat

    Specify the absolute path and name of the Simcenter Nastran input file. You can type the full path and name manually, or you can click and navigate to the file using the file selection dialog.

    Simcenter Nastran Executable Simcenter Nastran Executable [NASTRAN_INSTALL_DIR]\bin\nastran.exe

    Specify the absolute path and name of the Simcenter Nastran executable. You can type the full path and name manually, or you can click and navigate to the executable using the file selection dialog.

    SimcenterMP Options SimcenterMP options --wallshear on

    This setting enables import of wall shear stress for Simcenter Nastran.

  2. Save the simulation.