Adjusting the Parameters
Adjust the parameters that define the inflow volume, the vent refinement, the test chamber, and the closures so that they align with the new duct geometry.
To define the location and orientation of the misaligned
parts, set the parameters associated with the DuctCenter and
VentCenter coordinates:
-
Expand the
node and set the Value property for
each parameter as follows:
Parameter Value DuctCenterOrigin [-0.21, 0, 0] m DuctCenterXAxisInput [0, 0, 1] DuctCenterXYPlane [0, 1, 0] VentCenterOrigin [0.042, 0, 0] VentCenterXAxisInput [1, 0, 0] VentCenterXYPlane [0, 1, 0]
The current radius of the inflow volume is too small to cover the entire
duct inlet.
- To increase the radius of the inflow volume, select the 0.08 m. node and set Value to
The duct closure is also too small to close the duct inlet.
-
To increase the dimensions of the duct closure, expand the
and set the Value property for the duct
closure parameters as follows:
Parameter Value DuctClosureCorner1 [-0.05, -0.05, -0.005] DuctClosureCorner2 [0.05, 0.05, 0.005]
By observing the 01_InputGeometry
scene, you see the model of the inflow volume does not update automatically once the
parameters have been updated.
- To update the CAD model of the inflow volume, right-click the Update. node and select
-
Open the 01_InputGeometry,
02_Closures, and
03_VentRefinement scenes to check the closures, vent
refinement volume, inflow volume, and test chamber align with the new parameter
defintions.
01_InputGeometry:
02_Closures:
03_VentRefinement:
With the simulation parts aligned, the simulation is configured
to work with the new duct geometry.
-
To execute the simulation operations, click
(Play/Resume "Simulation Operations 1") in the solution toolbar.