Running the Simulation

As only the transverse magnetic potential is solved for in this axisymmetric simulation, the simulation runs quickly.

To run the simulation:
  1. In the Simulation toolbar, click (Run).
  2. When the simulation completes, open the Plots > Rectifier Currents plot and review the resulting waveforms.


    As expected, the current through the Secondary Load resistor is clearly a DC current with slight magnitude variation around 2 A. To reduce the variation further, you can increase the capacitance.