Setting Solver Parameters and Monitoring
Before you run the simulation you must define the time-step and stopping criteria. Additional reports are also necessary for monitoring core voltage waveforms within the circuit.
-
Select the 1/50/27.
node and set Time-Step to
This form of entry indicates that you want to have 27 discrete solution points for each current cycle (50 Hz).
- Select the Acceleration Method to Bi Conjugate Gradient Stabilized. node and set
- Select the 0.07 s. node and set Maximum Physical Time to
By default, Simcenter STAR-CCM+ monitors the Transverse Magnetic Potential
residual. Normalization is not necessary when monitoring this
residual.
- To deactivate residual normalization, select the Normalization Option to Off. node and set
For monitoring the solution, you define three reports: one each
for the current waveform through the primary and secondary coils,
and one for the load in the secondary circuit.
-
To define the current reports:
- Multi-select the three current report nodes, right-click, and select Create Monitor and Plot from Report. In the dialog, select Single Plot.
- Within the Plots node, rename Reports Plot to Rectifier Currents.
- Select the Rectifier Currents. node and set Title to
- Save the simulation.