Energy Source Option
Properties
Unless otherwise specified, the conditions below apply to fluid, porous, and solid regions.
- Energy Source Option
- Provides energy source options for the region.
- None
- Do not specify an energy source.
- Volumetric Heat Source
- Specifies a user-defined volumetric heat source in W/m3.
Activating this option when using the Segregated solver adds the following nodes under the Physics Values node:
- Volumetric Heat Source
- Energy Source Temperature Derivative
Activating this option when using the Coupled solver adds the following nodes under the Physics Values node:
- Volumetric Heat Source
- Energy Source Pressure Derivative
- Energy Source Temperature Derivative
- Energy Source Velocity Derivative
- Total Heat Source
- Specifies a user-defined total heat source in W.
Activating this option when using the Segregated solver adds the following nodes under the Physics Values node:
- Heat Source
- Energy Source Temperature Derivative
Activating this option when using the Coupled solver adds the following nodes under the Physics Values node:
- Heat Source
- Energy Source Pressure Derivative
- Energy Source Temperature Derivative
- Energy Source Velocity Derivative
If the profile for the heat source uses field functions or user code, the relation between the heat sources for individual cells, as specified by the field function, and the heat source for the entire region is:
where:
- is heat source for the cell.
- is total heat source in the volume or on the surface.
- is the cell volume.
- is the total volume.
For two-dimensional simulations, the volumes are replaced by surface areas.
- Specific Heat Source
- Specifies a user-defined specific heat source in W/kg.
Activating this option when using the Segregated solver or the Coupled solver adds the following nodes under the Physics Values node:
- Specific Heat Source
- Energy Source Temperature Derivative
- Heat Exchanger
- Specifies a heat exchanger
source term.
Activating this option when using the Segregated solver or the Coupled solver adds the following node under the Physics Conditions node:
- Heat Exchanger Exit Temperature Specification
- Heat Exchanger Minimum Temperature Difference
- Heat Exchanger Total Energy Rate
- Heat Exchanger Boundaries
- Heat Exchanger First Iteration
- Heat Exchanger Temperature
This option is only available with fluid and porous regions.