Specified y+ Heat Transfer Coefficient
When you use this option, note the following:
- This heat transfer coefficient and reference temperature pair is recommended to be used when coupling Simcenter STAR-CCM+ to other applications.
This heat transfer coefficient and reference temperature pair is less dependent on the mesh than the Local Heat Transfer Coefficient, gives better conditioned systems at solve time, and gives the fastest convergence for a given number of coupling-iterations. One coupling-iteration involves solving for the flow field given the initial solid wall temperature and then solving for the solid temperature field given and (that is, the near wall cell temperature) from the flow field computation. A single coupling-iteration can give good results, although at least two coupling-iterations are recommended.
For accuracy and numerical stability reasons, it is not recommended that you use alternative techniques of exchanging boundary conditions between Simcenter STAR-CCM+ and other applications. For example, when the fluid code passes the local heat flux to the solid code and the solid code passes the local wall temperature to the fluid code.
- This option can have implications for cycle averaging and mapping.
- It is recommended that you follow all recommendations for getting accurate results using the standard wall functions.
- The user-specified value of should be less than approximately 150. A value of 100 has been shown to work well.
- It is recommended that temperature-dependent fluid properties be used to ensure maximum accuracy.
If you use temperature-dependent fluid properties, all fluid properties should be temperature-dependent, rather than just some of the properties.