Importing Multiple Surface Data Files
STAR-CCM+ allows multiple surface input files of the same format to be imported simultaneously using the option.
Multiple files are selected by pressing the Ctrl or Shift key at the same time as selecting the file. In addition to the import options provided for single file input, the Region Mode option can further influence how regions are created when importing multiple surface data files as regions.
When importing surface mesh files, regardless of the Region Mode option that is selected, the imported surface contains two surfaces where one part of the geometry region joins the next. Additional advice on what to do about duplicate surfaces at mesh interfaces is given in the section on multi-region meshing.
Importing a series of surface mesh files one at a time produces the same result as importing the files simultaneously using the
option without merging the patches (or vertices in the case of STL files). This option is effectively the safest import option as no assumptions are made about how the surfaces are joined.Note the following:
- When you import multiple pro-STAR database files, it is assumed that the surface in each file is saved with the same database ID value.
- It is assumed that the same units have been used for all surface input files.
- Two or more surface data files of differing formats cannot be imported at the same time.
When you import multiple neutral format or native CAD files, regardless of the Region Mode option that is selected, the imported data contains two boundary surfaces at common interfaces where one geometry region joins the next. Additional advice on what to do about duplicate surfaces at mesh interfaces is given in the section on multi-region meshing.
Note the following:
- Importing a series of neutral format or native CAD data files one at a time produces the same result as importing the files simultaneously using either the Region Mode. This option is the safest import option as no assumptions are made about how the faces are joined. or option for
- Two or more neutral data files of differing formats or two or more native CAD data files of differing formats cannot be imported at the same time.