Running the Simulation
You run the transient simulation for a physical time of 4.0 s with a time step of 0.01 s. To stabilize the simulation, you ramp the CFL value of the coupled implicit solver linearly.
- Select the 0.01 s. node and set Time-Step to
-
Edit the
node and set the following properties:
Node Property Setting Load Balancing Enabled Activated Implicit Unsteady Maximum Sub-Steps 2000000 Update Frequency Once per Time Step Method Cell Cluster Method Absolute Length ${Parcel Diameter}*1.3 - Select Properties set Rebalance Frequency to 5. and in
- Select the 100. node and set Reordering Frequency to
-
Edit the
node and set the following properties:
Node Property Setting Coupled Implicit CFL Control Method Linear Ramp Target CFL 1000.0 End Iteration 20
To set the stopping criteria:
-
Select the Stopping Criteria node and set the following
values:
Node Property Setting Maximum Inner Iterations Maximum Inner Iterations 3 Maximum Physical Time Maximum Physical Time 4.0 s Maximum Steps Enabled Deactivated -
Click
(Run).
- When the simulation has finished running, save it.