Running the Simulation

You run the transient simulation for a physical time of 4.0 s with a time step of 0.01 s. To stabilize the simulation, you ramp the CFL value of the coupled implicit solver linearly.

To define the solver parameters:
  1. Select the Solvers > Implicit Unsteady node and set Time-Step to 0.01 s.
  2. Edit the Solvers > Lagrangian Multiphase node and set the following properties:
    Node Property Setting
    Load Balancing Enabled Activated
    Implicit Unsteady Maximum Sub-Steps 2000000
    Update Frequency Once per Time Step
    Two-Way Coupling > Volume Source Smoothing Method Method Cell Cluster
    Volume Source Smoothing Method > Cell Cluster > Cluster Length Method Absolute
    Cluster Length > Absolute Length ${Parcel Diameter}*1.3
  3. Select Partitioning > Load Balancing Options and in Properties set Rebalance Frequency to 5.
  4. Select the Solvers > DEM Solver node and set Reordering Frequency to 100.
  5. Edit the Solvers > Coupled Implicit node and set the following properties:
    Node Property Setting
    Coupled Implicit CFL Control Method Linear Ramp
    Coupled Implicit > Linear Ramp CFL Target CFL 1000.0
    End Iteration 20
To set the stopping criteria:
  1. Select the Stopping Criteria node and set the following values:
    Node Property Setting
    Maximum Inner Iterations Maximum Inner Iterations 3
    Maximum Physical Time Maximum Physical Time 4.0 s
    Maximum Steps Enabled Deactivated
  2. Click (Run).
  3. When the simulation has finished running, save it.