Setting up the Venting Rate
The mass flow rate and total temperature values for the venting inlets are calculated using the Thermal Runaway Battery Vent model. During venting, the battery cell looses mass, which affects its density.
-
Select the
and set the following properties:
Node Property Setting Mass Flow Rate Method Field Function Scalar Function Battery Vent Model Mass Flow Rate Total Temperature Method Field Function Scalar Function Battery Vent Model Total Temperature - Set the same properties for Air.Venting Inlet 2, Air.Venting Inlet 3, Air.Venting Inlet 4, Air.Venting Inlet 5 and Air.Venting Inlet 6.
To specifiy the material properties of the stack cells:
-
Select the
node and set the following properties:
Node Property Setting Density Method Field Function Field Function
Scalar Function Battery Vent Model Core Part Density - Save the simulation,