Setting up the Venting Rate

The mass flow rate and total temperature values for the venting inlets are calculated using the Thermal Runaway Battery Vent model. During venting, the battery cell looses mass, which affects its density.

To set up the venting rate:
  1. Select the Regions > Air > Boundaries > Air Venting Inlets > Air.Venting Inlet 1 > Physics Values and set the following properties:
    Node Property Setting
    Mass Flow Rate Method Field Function
    Scalar Function Battery Vent Model Mass Flow Rate
    Total Temperature Method Field Function
    Scalar Function Battery Vent Model Total Temperature
  2. Set the same properties for Air.Venting Inlet 2, Air.Venting Inlet 3, Air.Venting Inlet 4, Air.Venting Inlet 5 and Air.Venting Inlet 6.
To specifiy the material properties of the stack cells:
  1. Select the Continua > Battery Stacks > Models > Solid > Stack > Material Properties > Density node and set the following properties:
    Node Property Setting
    Density Method Field Function
    Field Function Scalar Function Battery Vent Model Core Part Density
  2. Save the simulation,