Creating an X-Y Plot of Fluid Film Thickness
Create an X-Y plot of the fluid film thickness along a plane section through the center of the wetted wall.
To create an X-Y plot of the fluid film thickness:
Create the plane section.
- Activate the Mesh Scene 1 in the Graphics window.
- Right-click the Derived Parts node and select .
-
In the
Create Section window, do the following:
A new derived part is created called plane section.
-
To view this part in the
Graphics window, open the
Derived Parts node and select
plane section.
The location of the line running down the surface is highlighted in the Graphics window.
- Rename the Wall Profile. node to
Create an X-Y plot for the fluid film thickness using the plane section.
- Right-click the Plots node and select .
- Rename the Film Thickness Profile. node to
-
With the
Film Thickness Profile node selected, in the
Parts property, click
(Custom Editor).
-
In the dialog that appears, expand the
Derived Parts node and select
Wall Profile.
- Click OK.
-
Select the
Scalar.
node and set the
Data Type property it to
-
Select the
(Custom Editor). node and in the Field Function property, click
-
In the
Scalar Function - Field Function dialog, select
.
-
Select the
(Custom Editor). node and in the Field Function property, click
-
In the
Scalar Function - Field Function dialog, select
Fluid Film Thickness.