Creating a Maximum Report, Monitor, and Plot

Create a report, monitor, and plot to monitor the maximum film thickness along the wetted wall.

Simcenter STAR-CCM+ can dynamically monitor virtually any quantity while the solution develops. To monitor a quantity, you set up a report that defines the quantity of interest and the parts of the region to monitor. A monitor is then defined based on that report. This monitor can also be used to create an appropriate X-Y graph plot.

To create a maximum report, monitor, and plot:

Set up a report to monitor the maximum film thickness along the wetted wall.
  1. Right-click the Reports node and select New > User > Maximum.


  2. Rename the Reports > Maximum 1 node to Maximum Film Thickness.
  3. Select the Maximum Film Thickness node and do the following:
    1. Set the Scalar Field Function to Fluid Film Thickness.


    2. In the Parts property, click (Custom Editor).
    3. In the dialog that appears, expand the Regions > Wetted Wall shell node and select Wetted Wall.


    4. Click OK.

Create a monitor and a plot for the report.

  1. Right-click the Maximum Film Thickness node and select Create Monitor and Plot from Report.


  2. Select the Monitors > Maximum Film Thickness Monitor node and check that the Trigger property is set to Time Step.


  3. Right-click the Plots > Maximum Film Thickness Monitor Plot node and select Open.