Setting Initial Conditions

You set the initial temperature, electric potential values, and mole fractions of the fuel and air streams.

To set the initial conditions:
  1. Multi-select the Initial Conditions > Static Temperature node of all continua and set Value to 973.15 K.
  2. In addition, for the Air and Fuel continua, set the following initial conditions:
    • Air:

      Node Property Setting
      Initial Conditions
      Species Specification Method Mole fraction
      Species Mole Fraction Value Click (Custom Editor) and set the following values:
      • N2: 0.79
      • O2: 0.21
    • Fuel:

      Node Property Setting
      Initial Conditions
      Species Specification Method Mole fraction
      Species Mole Fraction Value Click (Custom Editor) and set the following values:
      • H2: 0.97
      • H2O: 0.03
  3. Save the Simulation.