Setting Solver Parameters and Stopping Criteria

Set the appropriate solver parameters and stopping criteria for the simulation.

As you are solving an unsteady problem, it is necessary to specify the time-step size and the elapsed simulation time. This calculation runs for a maximum physical time of 0.2 seconds with a time-step size of 5.0E-4 s.

To set the solver parameters and stopping criteria:

  1. Edit the Solvers node and set the following properties:
    Node Property Setting
    Implicit Unsteady Time-Step 5.0E-4 s
    Segregated EMP Flow > Phase Coupled Velocity Implicit Under-Relaxation Factor 0.1
    Segregated EMP Flow > Pressure Under-Relaxation Factor 0.1
    Volume Fraction Implicit Under-Relaxation Factor 0.1
  2. Edit the Stopping Criteria node and set the following properties:
    Node Property Setting
    Maximum Physical Time Enabled Activated
    Maximum Physical Time 0.2 s
    Maximum Inner Iterations Maximum Inner Iterations 20
    Maximum Steps Enabled Deactivated
  3. Save the simulation.