Defining Boundary Conditions
Specify the temperature, the volume fraction of the dispersed phase, and the Mach number at the inlet and outlet.
To define the boundary conditions:
- Expand the node.
-
Edit the
Physics Values node, and set the following properties:
Node Property Setting Mach Number Value 0.4 Static Temperature Value 258.4 K -
Edit the
node, and set the following properties:
Node Property Setting Volume Fraction Value 3.42E-7 - Repeat the previous steps to set the boundary conditions for the Outlet, using the same settings that you entered for the Inlet.
Specify boundary conditions at the interface:
-
Edit the
node, and set the following properties:
Node Property Setting Physics Conditions Wall Surface Specification
Method Rough Physics Values Roughness Height
Value 0.1 mm - Save the simulation.