Defining Boundary Conditions

Specify the temperature, the volume fraction of the dispersed phase, and the Mach number at the inlet and outlet.

To define the boundary conditions:

  1. Expand the Regions > Region_1 > Boundaries > Inlet node.
  2. Edit the Physics Values node, and set the following properties:
    Node Property Setting
    Mach Number Value 0.4
    Static Temperature Value 258.4 K
  3. Edit the Phase Conditions > DMP Phase > Physics Values node, and set the following properties:
    Node Property Setting
    Volume Fraction Value 3.42E-7
  4. Repeat the previous steps to set the boundary conditions for the Outlet, using the same settings that you entered for the Inlet.
Specify boundary conditions at the interface:
  1. Edit the Regions > Region_1 > Boundaries > Foil [In-place 1] node, and set the following properties:
    Node Property Setting
    Physics Conditions
    Wall Surface Specification Method Rough
    Physics Values
    Roughness Height Value 0.1 mm
  2. Save the simulation.