Specifying Initial Conditions

By default, gravity is set to act along the z-axis, whereas the geometry for this tutorial requires it to act along the y-axis. The simulation also requires initial values for fluid velocity and temperature.

To specify the initial conditions:
Edit the Continua > Physics 1 node, and set the following properties:
Node Property Setting
Reference Values
Gravity Value [0,-9.81,0] m/s^2
Initial Conditions
Static Temperature Value 258.4 K