Analyzing the Results
After the simulation is complete, you visualize the results.
-
In the Graphics window, click through the Cylinder : Turbulence Kinetic Energy and Cylinder : Tumble-Y tabs.
The following plots display the results after the run:
At the ignition point of 720 deg crank angle, the turbulence kinetic energy value is 40.63439 J/kg.
The tumble-y value at ignition point is -0.04337333.
Examine the scenes for absolute pressure and velocity magnitude:
-
In your working directory, click through the saved image files for absolute pressure
and velocity magnitude. The saved scene files can be animated with a media program of your