Setting the Time-Step Size and the Wall Treatment
You enable automatic time-step control, which reduces the time-step size based on the start and end of fuel injection, and apply the Angelberger wall treatment formulation for diesel.
- Right-click the Solvers node and select Edit.
- In the Time Step Settings group box, activate Automatic, then click Settings.
-
In the Auto Time-Step Settings dialog, click through the
Global and the Injectors
tabs.
The Global tab displays the time-step settings that are valid throughout the simulation. The Injectors tab displays the time-step settings that are valid in certain intervals before and after fuel injection. For information on the calculation of the time-step size, see Simcenter STAR-CCM+ In-Cylinder Reference > Solvers: Time-Step Settings.
- Click OK.
To apply the Angelberger wall treatment formulation:
-
In the Wall Treatment group box, set the following
properties:
Property Setting Formulation Angelberger Formulation Angelberger Formulation Diesel - Click Apply, then Close.
-
Save the simulation
.