Monitoring Force Coefficients

By default Simcenter STAR-CCM+ provides a residuals plot which can be used to monitor the convergence of the solution. In addition to this, it is useful to create additional reports and monitors to help in assessing convergence.

Create two reports for monitoring force coefficients while the solvers are running:

  1. Right-click the Reports node and select New > Flow / Energy > Force Coefficient.
  2. Rename the Force Coefficient 1 node to Drag Coefficient.
  3. In the Properties window, set the following properties:
    Property Setting
    Reference Density 1.18 kg/m^3
    Reference Velocity 50 m/s
    Reference Area 8E-4 m^2
    Parts Regions > Body 1 > Boundaries > Cylinderwall
This report can be copied and used as a basis for the lift coefficient report:
  1. Copy and paste the Drag Coefficient node.
  2. Rename the copy to Lift Coefficient.
  3. In the Properties window, set the Direction to [0, 1, 0]

Create a monitor and plot from the reports:

  1. Multi-select the Drag Coefficient and Lift Coefficient nodes. Right-click the Drag Coefficient node and select Create Monitor and Plot from Report.
  2. Click Single Plot to display the coefficients for both probes in a single graph.

Two new monitors have been created, with their associated plot.

  1. Rename the Plots > Reports Plot to Force Coefficients Plot
  2. Save the simulation.