Monitoring Force Coefficients
By default Simcenter STAR-CCM+ provides a residuals plot which can be used to monitor the convergence of the solution. In addition to this, it is useful to create additional reports and monitors to help in assessing convergence.
Create two reports for monitoring force coefficients while the solvers are running:
- Right-click the node and select .
- Rename the Drag Coefficient. node to
-
In the
Properties window, set the following properties:
Property Setting Reference Density 1.18 kg/m^3 Reference Velocity 50 m/s Reference Area 8E-4 m^2 Parts
This report can be copied and used as a basis for the lift coefficient report:
- Copy and paste the node.
- Rename the copy to Lift Coefficient.
-
In the Properties window, set the Direction to [0, 1, 0]
Create a monitor and plot from the reports:
- Multi-select the and nodes. Right-click the node and select
- Click Single Plot to display the coefficients for both probes in a single graph.
Two new monitors have been created, with their associated plot.
- Rename the to
- Save the simulation.