Activating the Adjoint Models

The starting simulation file already contains model selections for the primal flow. Here, you activate the adjoint flow model.

The Spalart-Allmaras turbulence model has been selected for the flow physics in this simulation. As the simulation involves flow past a wing, which is one of the target scenarios for the Spalart-Allmaras model, it is reasonable to choose it here. Simcenter STAR-CCM+ can solve the adjoint for this turbulence model.

To activate the adjoint models:

  1. Right-click the Continua > Physics 1 node and choose Select Models....
    The Physics 1 Model Selection dialog appears.
  2. Select the following models sequentially:
    Group Box Model

    Optional Models

    Adjoint

    Adjoint Flow

    Adjoint Turbulence

    Adjoint Spalart-Allmaras

    Optional Models

    Mesh Deformation

    Optional Adjoint Models

    Adjoint Mesh Deformation

    NoteIn order to select the adjoint turbulence model Adjoint Spalart-Allmaras you must first select Spalart-Allmaras Turbulence for the primal flow. Otherwise the only available option is Adjoint Frozen Turbulence.
  3. Click Close.
  4. To view the active physics models, open the Physics 1 > Models node.