Analyzing with TAITherm
When you have finished the mapping work in Simcenter STAR-CCM+, export the data to the Patran Neutral file format (.ntl). See Exporting Mapped Data.
Then do as follows:
- Import the file into TAITherm.
- Set up the boundary conditions and thermal parameters in TAITherm and run the analysis.
- Prepare and export the results from the TAITherm file to the Patran Neutral file format. See Preparing a Model in TAITherm.
- Import the data into Simcenter STAR-CCM+.
- Export the Simcenter STAR-CCM+ fluid analysis results into the Patran Neutral file format.
- Back in the TAITherm file, import the Patran file created by Simcenter STAR-CCM+.
- If there are no error messages after importing the geometry, use TAITherm’s Import CFD Results feature to map the Simcenter STAR-CCM+ results to the geometry of the TAITherm file.
- Use TAITherm’s Model Parameter Display feature to view the fluid reference temperature values, and make sure they are consistent with those generated by Simcenter STAR-CCM+.