Setting the Solver Parameters and Stopping Criteria
Set the solver time-step and elapsed time.
-
To define the solver parameters, edit the
Solvers node and set the following properties:
Solver Node Property Value Implicit Unsteady Time-Step 0.01 s Enabled Activated DEM Solver Time Scale 0.4 Skin 2mm Coupled Implicit Freeze Flow Activated -
To define the stopping criteria, edit the
Stopping Criteria node and set the following properties:
Node Property Setting Maximum Inner Iterations Maximum Inner Iterations 1 Maximum Physical Time Maximum Physical Time 3.0 s Maximum Steps Enabled Deactivated - Save the simulation.