Setting Up Post-Processing

You set up scalar scenes for temperature, propane mass fraction, progress variable, and the error indicator and refinement level for the adaptive mesh refinement.

To set up post-processing:

  1. Expand the Scenes node and specify the properties of the scalar scenes as follows:
    Scene Action
    AMR Error Indicator Select the Scalar 1 > Scalar Field node and set Function to Error Indicator > Error Indicator of Progress Variable.
    AMR Refinement Level
    1. Select the Scalar 1 node and activate Display Mesh.
    2. Select the Scalar 1 > Scalar Field node and set Function to Refinement Level.
    Mass Fraction of Propane `Select the Scalar 1 > Scalar Field node and set Function to Mass Fraction > Mass Fraction of C3H8.
    Progress Variable Select the Scalar 1 > Scalar Field node and set Function to Progress Variable.
    Temperature Select the Scalar 1 > Scalar Field node and set Function to Temperature.
  2. To open the scenes, multi-select each of the [scene] nodes, right-click one of the selected nodes and select Open.
When species are set as Species For Tabulation within the FGM table parameters, you can create plots or scalar scenes to monitor these species. Monitoring CO in the fluid domain allows you to track the amount of CO emissions that are created and expelled from the domain.
  1. Save the simulation.