Exchanged Fields Reference
Simcenter STAR-CCM+ can export fluid pressure and wall shear stress to Simcenter Nastran and import solid displacement.
Exported Fields/Imported Fields Node Right-Click Actions
- Add Mechanical Field
- Allows you to select the following predefined mechanical fields for import or export:
[Exported Field] Properties
The fields under the Exported Fields node are subject to the following properties:
- Initialization Method
- Automatically set to User-defined Initialization Value. You can change the initialization value for this field under the node.
- Field Stencil
- Specifies the mesh stencil (Vertex or Face for surface meshes, and Vertex or Cell for volume meshes) from which Simcenter STAR-CCM+ maps the field data to be exported.
- Field Treatment
- Automatically set to Unmanaged. This setting indicates that Simcenter STAR-CCM+ does not perform any operation on this field before export.
- Scalar/Vector Function
- Automatically set to the field function that represents the exported field. If required, you can change the field function associated with the exported field.
[Imported Field] Properties
- Initialization Method
- Automatically set to User-defined Initialization Value. You can change the initialization value for this field under the node.
- Field Stencil
- Specifies the mesh stencil (either Vertex, Face, or Cell) to which Simcenter STAR-CCM+ maps the imported field data.
- Field Treatment
-
- Managed: at the coupled
boundaries, Simcenter STAR-CCM+
automatically defines morpher settings using the imported solid
displacement:
Imported Field Wall Boundary Conditions and Values Displacement If the morpher is active on the fluid region: - Morpher Specification
- Set to Displacement.
- Morpher Displacement Specification
- Set to Total.
- Morpher Total Linear Displacement
- Set to Interoperability, which indicates that the boundary value is automatically set using imported data.
This option is only available when the fluid region has morphing motion and the fluid continuum contains the Co-Simulation Mechanical Treatment model.
- Unmanaged: Simcenter STAR-CCM+ does not use the imported data to set boundary conditions. You are responsible for setting all boundary conditions manually, using the field functions that store the imported data.
- Managed: at the coupled
boundaries, Simcenter STAR-CCM+
automatically defines morpher settings using the imported solid
displacement:
- Scalar/Vector Function
- Displays the field function that stores the imported field. Read-only.