Restarting the Co-Simulation
You can run a co-simulation in multiple stages. Simcenter STAR-CCM+ co-simulation supports most of the common restart scenarios, providing that the partner simulations were in a consistent state when the co-simulation stopped.
Note | Do not change any properties while the co-simulation is running. Any discrepancy in the settings can break the synchronization between the coupled simulations. |
To restart a co-simulation:
- If one or both simulations are in an inconsistent state, either clear the solution in both simulations, or step each simulation until both reach a consistent state.
-
In both or one of the simulations, change the settings as required.
Changes to the regions layout, such as combining regions in both or one of the simulations, are not supported in restart scenarios.
To restart the co-simulation:
-
Press
(Run) in one of the simulations.
If a synchronization problem occurs, clear the solution in both simulations and then press Run.