Setting Up the Combustion Models

Here, you select the combustion and ignition models. To save runtime for this tutorial, you de-activate the liquid film model that was introduced in the Gasoline Engine: Charge Motion tutorial.

To set up the physics models:
  1. Edit the Models node and, in the Enabled Models group-box, de-select Liquid Film.
  2. Select the following models, then click Close:
    Group Box Model
    Optional Models Combustion
    Combustion Model ECFM-3Z
    Ignition Model Spark Ignition
    Spark Ignition Model FI Spark-Ignition
  3. Save the simulation .