Setting the Re-Mesh Criteria
During the running simulation, Simcenter STAR-CCM+ In-cylinder re-meshes the geometry based on certain re-mesh criteria to ensure good cell quality for all crank angles. The default re-mesh criteria are based on best practices and are suitable in most cases. Here, you set re-mesh criteria that are more suitable for this engine geometry.
- Right-click the Mesh node and select Edit Mesh Settings.
- In the Edit tab, click Re-mesh Criteria.
-
In the Bad Morphed Cell Criteria (all must be satisifed)
group box, set the following properties:
Property Setting Min Cell Aspect Ratio 2 0.82 Min Cell Quality 2 0.025 - Click Apply, then Close.
-
Save the simulation
.