Boundary Values and Initial Conditions Reference
This section contains reference descriptions of boundary and initial condition values that are available for the Thin Film model.
The boundary values are set according to the boundary type, and by methods that are selected in corresponding nodes in the Conditions node. They are entered as scalar profiles.
Fog Layer Thickness
This value node is available when the Defogging model is selected. It is visible if Fog Layer is selected as the Option property for the Thin Film Option node of the Conditions node.
Ice Layer Thickness
This value node is available when the Deicing model is selected. It is visible if Ice Layer is selected as the Option property for the Thin Film Option node of the Conditions node.
Vapor Humidity
This value node is available when the Defogging model is selected. It is visible if Vapor Humidity is selected as the Option property for the Vapor Mass Fraction Specification node of the Conditions node.
Vapor Mass Fraction
This value node is available when the Defogging model is selected. It is visible if Vapor Mass Fraction is selected as the Option property for the Vapor Mass Fraction Specification node of the Conditions node.