Preparing the Simcenter STAR-CCM+ Model

Prepare the fluid model simulation in Simcenter STAR-CCM+.

The Simcenter STAR-CCM+ model defines a fluid domain surrounding the solid plate. In the simulation, air enters the fluid domain at 10 m/s. The outlet boundary is modeled as a Pressure Outlet, and the top and sides of the domain are specified as Symmetry boundaries. Flow is defined as incompressible, and turbulence is modeled using the K-Omega model.

The dimensions of the fluid domain are shown in the above diagram.