Setting Solver Parameters and Stopping Criteria
Set the appropriate solver parameters and stopping criteria for the simulation. As you are solving an unsteady problem, it is necessary to specify the time-step size and the elapsed simulation time.
This calculation runs for 5 x 10-5 s with a time-step size of 10-7 s, so requires 500 time-steps.
To set the solver parameters and stopping criteria:
-
Edit the
Solvers node and set the following property:
Node Property Setting Implicit Unsteady Time-Step 1e-7 s -
Edit the
Stopping Criteria node and set the following properties: