Selecting the Physics Models

Physics models define the physical variables and phenomena in the simulation. An incompressible isothermal turbulent flow is sufficient for this analysis. Use the segregated flow model with the k-omega turbulence model.

To select the physics models:

  1. For the physics continuum, Continua > Physics 1, in the Enabled Models group box, deactivate Two-Dimensional.
  2. Select the following models in order:

    Group Box

    Model

    Space

    Axisymmetric

    Time

    Steady

    Material

    Liquid

    Flow

    Segregated Flow

    Gradients (Selected automatically)

    Equation of State

    Constant Density

    Viscous Regime

    Turbulent

    Reynolds-Averaged Navier-Stokes (Selected automatically)

    Reynolds-Averaged Turbulence

    K-Omega Turbulence

    SST (Menter) K-Omega (Selected automatically)

    Wall Distance (Selected automatically)

    All y+ Wall Treatment (Selected automatically)

  3. Click Close.
  4. Save the simulation.