Setting Up the Solution History File

To save solution data at regular intervals while the simulation is running, you create a solution history file (.simh). In this tutorial, you save the pressure data on the cylinder wall and on the plane section, so that you can perform surface spectral analysis after the simulation completes.

To set up the solution history file:
  1. Right-click the Solution Histories node and select New....
  2. In the Save dialog, set File Name to cylinderPressureData, then click Save.
  3. Edit the Solution Histories > cylinderPressureData node and set the following properties:
    Node Property Setting
    cylinderPressureData Functions Pressure
    Inputs
    • Regions > Body 1 > Boundaries > Cylinderwall
    • Derived Parts > Plane Section
    Update Enabled Activated
    Trigger Time Step
    Time-Step Frequency Frequency 1
    Start 50
  4. Save the simulation.