Defogging Model Properties

LimitSuperSaturation

Controls whether supersaturation (humidity exceeding 100%) is prevented.

Activated

Prevents supersaturation.

Deactivated

Allows supersaturation.

Defogging Model Expert Properties

The settings within the Expert category can be useful if you are thoroughly familiar with the theoretical aspects of this model and the discretization techniques that are used in Simcenter STAR-CCM+. The values in that category reflect both the design of the model and the discretization approaches that have been optimized for accuracy and performance. If you are not familiar with these details, do not change any settings.

Secondary Gradients

Neglect or include the boundary secondary gradients for diffusion and/or the interior secondary gradients at mesh faces.

On

Include both secondary gradients.

Off

Exclude both secondary gradients.

Interior Only

Include the interior secondary gradients only.

Boundaries Only

Include the boundary secondary gradients only.

Convection

Selects the convection scheme that is used. For guidance as to convection scheme selection, see Diffusion Term, p.3755.

1st-order

Selects the first-order upwind convection scheme.

2nd-order

Selects the second-order upwind convection scheme.

Cemp

Specifies the C empirical coefficient.