Setting the Solver Parameters and Stopping Criteria

You set the simulation to stop after 331.0 seconds with a time-step of 1.0 second.

To set the solver parameters and stopping criteria:
  1. Select the Solvers > Implicit Unsteady node and set Time-Step to 1.0 s.
  2. Select the Solvers > Segregated Energy node and set the following properties:
    Property Setting
    Fluid Under-Relaxation Factor 0.99
    Solid Under-Relaxation Factor 0.999
  3. Expand the Stopping Criteria node and set the following properties:
    Node Property Setting
    Maximum Physical Time Maximum Physical Time 331.0 s
    Maximum Steps Enabled Deactivated
  4. Save the simulation.