Visualizing the Results
To examine irradiation, temperature, and other results from the converged solution, look at the plots and the scene.
-
At the end of the calculation, to view the irradiation variation at the solid-fluid interface, activate the
Irradiation1 Monitor Plot display.
-
To see the temperature result for the converged solution, look at the
Scalar Scene 1 display.
-
To make the display smoother, set
Contour Style to
Smooth Filled.
The contours of the scalar display now appear smooth.
-
Look at the
Reports Plot display to see the graph of the maximum temperature monitors for the fluid and the solid.
-
To zoom in on the relevant part of the graph, edit the
node and set the following properties:
Node Property Setting Bottom Axis Minimum 50 Left Axis Minimum 470 Maximum 570 Major Labels
Spacing 10 The graph now appears as shown below.
-
To determine the heat flux that is leaving the system at the top boundary, run the
HeatFlux1 report.
The
Output window shows that heat flux.


- Save the simulation.