Visualizing the Results

To examine irradiation, temperature, and other results from the converged solution, look at the plots and the scene.

  1. At the end of the calculation, to view the irradiation variation at the solid-fluid interface, activate the Irradiation1 Monitor Plot display.


  2. To see the temperature result for the converged solution, look at the Scalar Scene 1 display.


  3. To make the display smoother, set Contour Style to Smooth Filled.
    The contours of the scalar display now appear smooth.

  4. Look at the Reports Plot display to see the graph of the maximum temperature monitors for the fluid and the solid.


  5. To zoom in on the relevant part of the graph, edit the Plots > Reports Plot > Axes node and set the following properties:
    Node Property Setting
    Bottom Axis Minimum 50
    Left Axis Minimum 470
    Maximum 570
    Major Labels Spacing 10
    The graph now appears as shown below.

  6. To determine the heat flux that is leaving the system at the top boundary, run the HeatFlux1 report.
The Output window shows that heat flux.

  1. Save the simulation.