Migrating from EDEM

This section provides information to help you convert an EDEM simulation to run under Simcenter STAR-CCM+.

To convert an EDEM simulation to run under Simcenter STAR-CCM+, remember:

  • Plots of time-dependent quantities should be set before simulation in Simcenter STAR-CCM+ and after simulation in EDEM.
  • Geometry meshing requirements are different in Simcenter STAR-CCM+ compared to EDEM (concepts of volume mesh, regions).
  • Cell size should be at least four times particle size, and as much larger as practical.
  • Optimal number of CPUs: Simcenter STAR-CCM+ readily scales up to at least 64 CPUs. These CPUs can be distributed through a cluster.
  • The Hertz-Mindlin model in Simcenter STAR-CCM+ uses two coefficients of restitution, one for energy dissipation due to damping of normal component of contact force, another for energy dissipation due to damping of tangential component of contact force. The Hertz-Mindlin model in EDEM uses only one parameter for coefficient of restitution.
  • Differences between EDEM and Simcenter STAR-CCM+ terminology include the following:
    EDEM Simcenter STAR-CCM+
    Write-out interval Auto-save time
    Factory Injector
    Rayleigh timestep Time scaling factor
    Simulated time Time stopping criteria parameter