Running the Simulation

You run the film casting simulation in steady-state until the relative change in residuals is less than 10-8.

To run the simulation:
  1. Create monitor-based stopping criteria:
    1. Right-click the Stopping Criteria node and select New Monitor Criterion.
    2. In the Select Monitor dialog, select ExtraStress1, then click OK.
    3. Create three more monitor criteria for the following monitors:
      • Film Thickness
      • Momentum
      • Temperature
    4. Within the Stopping Criteria node, multi-select the ExtraStress1 Criterion, Film Thickness Criterion, Momentum Criterion, and Temperature Criterion nodes, and set the following properties:
      Node Property Setting
      ExtraStress1 Criterion Option Relative Change
      Film Thickness
      Momentum
      Temperature
      Relative Change Relative Change 1.0E-8
  2. Select the Stopping Criteria > Material Relaxation node and deactivate Enabled.
  3. Click (Run) to run the simulation.
  4. When the simulation is complete, save it.