Setting Initial Conditions and Reference Values

Set the initial conditions and reference values for the physics continuum.

To set the initial conditions and reference values:

  1. Edit the Continua > Physics 1 > Models > Multiphase > Phases node and set the following properties:
    Node Property Setting
    Water > Initial Conditions
    Turbulence Specification Method Intensity + Length Scale
    Turbulent Length Scale Value 0.005 m
    Velocity Value [1.23, 0.0] m/s
    Volume Fraction Value 0.8
    Air > Initial Conditions
    Velocity Value [1.61, 0.0] m/s
    Volume Fraction Value 0.2
Set the reference values for the Physics 1 continuum.
  1. Edit the Reference Values node and set the following properties:
    Node Property Setting
    Reference Density Value 1000 kg/m^3
    Gravity Value [-9.81, 0.0] m/s^2
  2. Save the simulation.