You create two mesh thresholds to display the temperature in the exhaust manifold volume.
-
Create a mesh threshold that contains all cells above Z = 0.0 m.
-
Right-click the Derived Parts node and select .
-
In the
Create Threshold dialog, set the following properties:
Properties
|
Select
|
Input Parts
|
|
Scalar
|
Position[Z]
|
Extraction Mode
|
All Above
|
Threshold Value
|
0.0 m
|
Display
|
New Surface
Displayer
|
-
Click
Create followed by
Close.
-
Select the
Threshold node and rename it to
Mesh Threshold 1.
-
Create a mesh threshold that contains all cells with x coordinate greater than 0.0315 m.
-
Right-click the Derived Parts node and select .
-
In the
Create Threshold dialog, set the following properties:
Properties
|
Select
|
Input Parts
|
|
Scalar
|
Position[X]
|
Extraction Mode
|
All Above
|
Threshold Value
|
0.0315 m
|
Display
|
No Displayer
|
-
Click
Create followed by
Close.
-
Select the
Threshold node and rename it to
Mesh Threshold 2.
-
Save the simulation.