Setting Initial Conditions and Boundary Settings

To achieve a Reynolds number of 500 for this gas and pipe diameter, you require a mean velocity of 0.429 m/s.

To assist solution convergence, define the initial condition for velocity:

  1. Select the Physics 1 > Initial Conditions > Velocity node and set the Value to [0.429, 0.0, 0.0] m/s.

Set the same velocity on the Inlet boundary.

  1. Select the Regions > Fluid > Boundaries > Inlet > Physics Values > Velocity Magnitude node and set the Value to 0.429 m/s.