Setting Reference Values
Set the reference values for the physics continuum.
The reference gravity, density, and pressure for the simulation are set up. The main modeling choice here is to take the reference density for the buoyancy term from the liquid phase density. This choice allows the simulation to move smoothly from a zero initial field for pressure and vapor volume fraction, rather than requiring a hydrostatic initial pressure field.
To set the reference values:
Set the reference values for the
Physics 1 continuum.
-
Edit the
Reference Values node and set the following properties:
Node Property Setting Gravity Value [-9.81, 0.0] m/s^2 Reference Density Value $InletDensity Reference Pressure Value $SystemPressure - Save the simulation.