Setting Boundary Conditions
Define the boundary types and specify the appropriate property values.
Specify conditions on the wall and inlet boundaries.
To set the boundary conditions:
-
Edit the
node and set the following properties:
Node Property Setting Condition Heat Flux Method Field Function Scalar Function WallHeatFluxIterationRamp
Set the phase conditions for the liquid and vapor phases at the inlet. The turbulence intensity and turbulent viscosity ratio are modified so that the settings match the Initial Conditions.
-
Edit the
node and set the following properties:
Node Property Setting Static Temperature
Value $InletTemperature Turbulence Intensity
Value 0.01 Turbulent Viscosity Ratio
Value 200 Velocity Magnitude
Method Field Function Scalar Function Volume Fraction
Value 1.0 Node Property Setting Sauter Mean Diameter
Value 0.001 Static Temperature
Value $SaturationTemperature Velocity Magnitude
Method Field Function Scalar Function Volume Fraction
Value 0.0
Define the outlet boundary. The static temperature for the liquid and vapor phases at the outlet are set. These values are the same as for the inlet.
-
Edit the
node and set the following properties:
Node Property Setting Static Temperature
Value $InletTemperature Turbulence Intensity
Value 0.01 Turbulent Viscosity Ratio
Value 10 Volume Fraction
Value 1.0 Node Property Setting Sauter Mean Diameter
Value 0.001 Static Temperature
Value $SaturationTemperature Volume Fraction
Value 0.0
- Save the simulation.