Co-Simulation Zones Reference

Co-simulation zones allow you to couple Simcenter STAR-CCM+ boundaries with corresponding Simcenter Amesim ports.

Zones Manager Properties

Number of Zones
Displays the number of zones defined for this link. Read-only.

Zones Manager Right-Click Actions

New
Adds a co-simulation zone under the Zones node.

Zone Properties

Index
Specifies a unique index which identifies a zone. Read-only.
Zone Type
Specifies what type of Simcenter STAR-CCM+ objects are assigned to the co-simulation zone for coupling. In co-simulation with Simcenter Amesim the available option is Surface Zone.

Zone Conditions and Values

The conditions and values of a co-simulation zone allow you to specify the coupled boundaries and the fields that are exchanged during the co-simulation.

Coupled Model Parts
Displays the Simcenter STAR-CCM+ boundaries that exchange data with Simcenter Amesim through this co-simulation zone. This property is read-only. To assign a boundary to a co-simulation zone, use the External Code Coupling Specification condition for the boundary.
Exported Fields, Imported Fields
Allow you to specify the fields that are exchanged during the co-simulation using either predefined fields or auxiliary fields. For more information, see Exchanged Fields Reference.